Date: 5/31/2003
|
|
|
Prepared By: Global Energy
|
Microturbines and Gas Turbines
Basics:
1 Therm = 100,000 BTU
1 cubic foot of gas = 1,000 BTU
1 mcf = 1,000 cu.ft. = 1,000,000 BTU or 1 mmbtu
|
Unit
|
Capstone 30 kw
|
Capstone 60 kw
|
Ingersoll-Rand 70 kw
|
Ingersoll-Rand 250 kw
|
Ingersoll-Rand 1700 kw
|
Solar Cat Taurus 60 5,500 kw
|
Fuel Cell
|
|
kilowatts /hr
|
30
|
60
|
70
|
250
|
1700
|
5376
|
100
|
|
|
|
|
|
|
|
|
|
|
heat rate LVH (btu per kw)
|
13,700
|
12,200
|
13,550
|
10,700
|
10,500
|
11,225
|
8,000 est.
|
|
Fuel Flow BTU/hr (HHV)
|
411,000
|
804,000
|
948,500
|
2,975,000
|
17,850,000
|
61,737,500
|
800,000
|
|
|
|
|
|
|
|
|
|
|
Fuel Flow mcf per hour
|
.411
|
.804
|
.949
|
2.98
|
17.85
|
61.74
|
.800
|
|
|
|
|
|
|
|
|
|
|
Fuel Flow at 100% output - mcf per day
|
9.86
|
19.30
|
22.76
|
71.40
|
428.40
|
1,481.70
|
19.2
|
|
|
|
|
|
|
|
|
|
|
Total Exhaust Energy in btu
|
310,000
|
541,000
|
682,920
|
2,171,750
|
12,495,000
|
39,900,000
|
600,000
|
|
|
|
|
|
|
|
|
|
|
Design Life Hours
|
50,000
|
50,000
|
80,000
|
80,000
|
80,000
|
100,000
|
7,000
|
|
|
|
|
|
|
|
|
|
|
Global Energy Pricing Unit Cost
|
$26,000
(84 units available)
$35,500 new from factory
|
$55,500 new
|
$100,000 new
|
$300,000+ new
|
$1,700,000 new
|
$2,100,000 (36 units available)
|
$1,300,000
|
|
Cost Per Unit Life per kwh
|
$.0173
|
$.0167
|
$.0143
|
$.0125
|
$.0096
|
$.0039
|
$1.86
|
|
|
|
|
|
|
|
|
|
|
Overhaul Cost at End of Life (est)
|
$5,000
|
$15,000
|
$15,000
|
$60,000
|
$300,000
|
Requires periodic overhauls and
checks
|
Buy new unit
|
|
|
|
|
|
|
|
|
|
|
Notes
|
|
|
|
|
|
Units are trailer mounted
|
Still under development
|
Notes: Exhaust heat can be used to heat liquids, in a
chiller, or through a dehumidification unit.
|