Text | All Copeland Horizontal Fuel Gas Boosters (FGB) compressor oil level | 001



Capstone

Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 • USA Telephone: (818) 734-5300 • Facsimile: (818) 734-5320 • Website: www.microturbine.com

Service Bulletin SB0077

Date: From: Subject:

Affected

All Copeland Horizontal Fuel Gas Boosters (FGB) compressor units.

Summary

The FGB compressor oil level must not exceed the recommended levels or the compressed gas going into the MicroTurbine will be contaminated with oil.

Perform a visual check of the upper and lower site glass to make sure levels are appropriate:

• Under normal operating conditions (~1,800 RPM), the oil level should be near the center of the lower site glass. If the lower site glass is less then 50 percent, add compressor oil to this level.

• At full speed (~4,800 RPM), the oil level should be near the center of the upper site

September 2005

Capstone Technical Support

Copeland Horizontal FGB Compressor Oil Level

glass and the lower site glass should be 100% full. then 50 percent, add compressor oil to this level.

If the upper site glass is less

Upper Site Glass

Lower Site Glass

Primary Separator Schrader Valve

NOTE: For further technical details on the Copeland Horizontal FGB, please refer to the “Horizontal Gas Booster Technical Reference,” 410047-001. If the compressor needs removal, please refer to the “Horizontal FGB Compressor Replacement Work Instruction,” 440127-001 for further details.

450061-001 Rev A (September 2005) Page 1 of 3

This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.

Image | All Copeland Horizontal Fuel Gas Boosters (FGB) compressor oil level



all-copeland-horizontal-fuel-gas-boosters-fgb-compressor-oil-level-
Capstone Turbine For Sale - Microturbine C30 C65 C200 C600 C800 C1000 - Go to microturbine website

Search Engine Contact: greg@globalmicroturbine.com