C65 & C65-ICHP MicroTurbine Natural Gas

Achieve ultra-low emissions and reliable electrical/thermal generation from natural gas.

• Ultra-low emissions

• One moving part: Minimal maintenance and downtime

• Patented air bearing: No lubricating oil or coolant

• 5 and 9 year Factory Protection Plans available

• Remote monitoring and diagnostic capabilities

• Integrated utility synchronization and protection

• Small, modular design allows for easy, low-cost installation

• Reliable: Tens of millions of run hours and counting

C65 MicroTurbine

Electrical Performance(1)

Electrical Power Output Voltage

Electrical Service Frequency

Maximum Output Current Electrical Ef ciency LHV

Fuel/Engine Characteristics(1)

Natural Gas HHV Inlet Pressure(3) Fuel Flow HHV Net Heat Rate LHV

2 NOx / Electrical Output(4)

Exhaust Gas Flow Exhaust Gas Temperature

65 kW

400 to 480 VAC

3-Phase, 4 wire

50/60 Hz, grid connect operation 10-60 Hz, stand alone operation 100A, grid connect operation 127A, stand alone operation(2) 29%

30.7 MJ/m3 to 47.5 MJ/m3 (825 to 1,275 BTU/scf) 517-552 kPa gauge (75-80 psig)

888 MJ/hr (842,000 BTU/hr)

12.4 MJ/kWh (11,800 BTU/kWh)

0.16 g/bhp-hr (0.46 lb/MWhe) 0.49 kg/s (1.08 lbm/s)

309°C (588°F)

C65-ICHP MicroTurbine

Exhaust Characteristics(1) C65

NOx Emissions at 15% O (4) 9 ppmvd (19 mg/m3)

Reliable power when and where you need it. Clean and simple.

Image | C65 & C65-ICHP MicroTurbine Natural Gas Achieve ultra-low emissions and reliable electrical/thermal generation from natural gas.



c65-and-c65-ichp-microturbine-natural-gasachieve-ultra-low-emissions-and-reliable-electrical-thermal-generation-from-natural-gas
Capstone Turbine For Sale - Microturbine C30 C65 C200 C600 C800 C1000 - Go to microturbine website

Search Engine Contact: greg@globalmicroturbine.com