Global Microturbine - Global Energy LLC


Publication Title | C65 & C65-ICHP Natural Gas MicroTurbine Performance Specifications(1)

Microturbine Search Engine Series

Capstone Turbine Publications search was updated real-time via Filemaker on:

Capstone Turbine Publications | Return to Search List

Search Completed | Title | C65 & C65-ICHP Natural Gas MicroTurbine Performance Specifications(1)
Original File Name Searched: PDS_NatGasC65&C65-ICHP-Int1R.pdf | Google It | Yahoo | Bing



Page Number: 001
Previous Page View | Next Page View

Text | C65 & C65-ICHP Natural Gas MicroTurbine Performance Specifications(1) | 001



PRODUCT DATA SHEET

C65 & C65-ICHP Natural Gas MicroTurbine Performance Specifications(1)

Electrical Performance

Electrical Power Output

Voltage Electrical Service Frequency

Maximum Output Current

Electrical Efficiency LHV

Fuel/Engine Characteristics

Natural Gas HHV

Inlet Pressure(3)

Fuel Flow LHV

Generator Heat Rate LHV Exhaust Characteristics Exhaust Gas Flow

Exhaust Gas Temperature

Exhaust Emissions

NOx Emissions @ 15% O2 NOx/Electrical Output(4) NOx/Electrical & Thermal Output(5) C65-ICHP Heat Recovery(6) Integrated Heat Recovery Module Type Hot Water Heat Recovery

Total System Efficiency LHV

Dimensions & Weight

Width x Depth x Height

Weight - Grid Connect Model Weight - Dual Mode Model Certifications

65 kW

400 to 480 VAC

3-Phase

50/60 Hz, Grid Connect Operation 10–60 Hz, Stand Alone Operation

100A, Grid Connect Operation 127A, Stand Alone Operation(2)

29%

825 to 1,275 BTU/scf

2.9 psig (0.20 barg) utility, 65 psig (4.5 barg) Engine/MT 765,000 BTU/hr (807,000 kJ/hr)

11,000 BTU/kWh (11,600 kJ/kWh)

1.08 lb/sec (0.49 kg/s)

588 ̊F (309 ̊C)

C65

< 5 ppmvd

< 0.28 lb/MWh (0.095 g/bhp-hr)

Copper Core

408,000 BTU/hr (120 kW) 82%

C65

30 x 77 x 83 inches

1,671 lbs (758 kg) 2,471 lbs (1,121 kg)

C65-ICHP

< 5 ppmvd

< 0.28 lb/MWh (0.095 g/bhp-hr) < 0.10 lb/MWh (0.034 g/bhp-hr)

Stainless Steel Core

251,000 BTU/hr (74 kW) 62%

C65-ICHP

30 x 77 x 94 inches 2,200 lbs (1,000 kg) 3,000 lbs (1,364 kg)

C65

Certified to UL 2200 and UL 1741 for natural gas operation (UL files AU2687, E209370)

Meets statewide utility interconnection requirements for California Rule 21 and the New York State Public Service Commision Materials Equipment Acceptance (MEA) approval for New York City

Models available with optional equipment for CE Marking

Certification to California Air Resources Board (60 kw)

(1) Nominal full power performance at ISO conditions: 59 ̊F, 14.696 psia, 60% RH (2) With linear load

(3) Inlet pressure for standard natural gas at 1,000 BTU/scf

Specifications are not warrantied and are subject to change without notice.

(4) Exhaust emissions with methane fuel.

(5) C65-ICHP exhaust emissions with 408,000 BTU/hr (120 kW) heat recovery. (6) Heat recovery for water inlet temperature of 100 ̊F (38 ̊C) and

flow rate of 40 GPM (2.5 l/s)

21211 Nordhoff Street • Chatsworth • CA • 91311 • 877.716.2929 • 818.407.3770 • www.microturbine.com C65-ICHP

PDS-C65&C65ING-I-08/06

Image | C65 & C65-ICHP Natural Gas MicroTurbine Performance Specifications(1)



c65-and-c65-ichp-natural-gas-microturbine-performance-specifications1
Capstone Turbine For Sale - Microturbine C30 C65 C200 C600 C800 C1000 - Go to microturbine website

Search Engine Contact: greg@globalmicroturbine.com