Capstone MicroTurbineTM

The Product

Features Benefits

• Load-following 15-30 kW

• Fuel input as low as 350 Btu/scf

• 360-528 VAC, 50/60 Hz 3-phase, 3- or 4-wire wye 46ARMS/phase max continuous

• Maintenance-free air bearings

• No liquid lubricants

• No liquid coolants

• Sour gas tolerant (up to 70,000 ppm)

• Digital power controller

• Built-in display and user interface

• Built-in protective relays

• Built-in MultiPacking of 2-20-units (unlimited via grid connect)

• Renewable energy from waste • Greenhouse gas reduction

• Ultra-low emissions

• Minimal maintenance

• Direct2GridTM interconnection

• No fluid storage, changes, disposal

• Uncontaminated exhaust heat for CHP

• Phase-to-phase balance (0-100%) on stand-alone units

• Small footprint

• Vibration-free, quiet operation

• Easy indoor/outdoor/rooftop siting

• Zero hardware arraying (up to 600 kW) • Optional remote monitoring

C30 HP Net Power and Efficiency at Ambient Temperature, Sea Level

Compliances

IEEE 519 CEC Rule 21 NYPSC DG EPA Exempt CA AQMD Exempt WY DEQ Exempt NEMA 3R / IP 14 Others*

Power Efficiency

30.0 27.5 25.0 22.5 20.0 17.5 15.0 12.5 10.0 7.5 5.0

2.5 0.0

30.0 27.5 25.0 22.5 20.0 17.5 15.0 12.5 10.0 7.5 5.0

2.5 0.0

-5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 8590 95100105110115120125 Ambient Temperature (F)

Other packaging options also available.

Performance

Landfill or digester gas

Emissions:

NOx

Intake/Exhaust

Fuel flow (methane-HHV) Exhaust gas temperature Mass flow

Total exhaust energy

Power

30 kW net (+0/-1)

38.2 kVA max @ 480 VAC

<9 ppmV @ 15% O2 (<0.49 lb/MWh)

457,000 kJ/hr (433,000 Btu/hr) 275 ̊C (530 ̊F)

0.31 kg/s (0.68 lb/s)

327,000 kJ/hr (310,000 Btu/hr)

Heat Rate (LHV)

13,800 kJ (13,100 Btu) / kWh

Full Load Specifications @ ISO Conditions (15oC / 59oF @ sea level)

Dimensions

H: 1900mm (74.8”) W: 714mm (28.1”) D: 1344mm (52.9”)

Weight

478 kg (1052 lb)

Sound

65dBA @ 10 m (33 ft)

58dBA @ 10 m (33 ft) with optional silencer

CE LWA 98 compliant

Pressure Requirements

Btu/scf (HHV)

psig

>1000

55

>600

65

>350

75

* See www.microturbine.com/compliance for detail

Fuel heat content: 12.8 to 42.1 MJ/m3 (350 to 1130 Btu/scf) HHV methane.

The manufacturer reserves the right to change or modify, without notice, the design or equipment specifications without incurring any obligation either with respect to equipment previously sold or in the process of construction. The manufacturer does not warranty the data on this document. Warrantied specifications are documented separately.

CAPSTONE TURBINE CORPORATION

www.microturbine.com

CAPSTONE C30 Biogas

Efficiency (LHV)

26% (± 2)

© 2002 Capstone Turbine Corp. • 05/2002 ss-bio • p/n: 510719-004

ISO Conditions

Net Power (kW)

Net Efficiency (%)