Capstone MicroTurbineTM

The Product

Features Benefits

• Load-following 0-30 kW

• 360-528 VAC, 50/60 Hz

(Stand-alone 360-480 VAC, 10-60 Hz)

3-phase, 3- or 4-wire wye (4-wire for stand-alone) 46ARMS/phase max continuous

• Grid-connect and/or stand-alone

• Maintenance-free air bearings

• No liquid lubricants

• No liquid coolants

• Sour gas tolerant (up to 70,000 ppm)

• Digital power controller

• Built-in display and user interface

• Built-in protective relays

• Built-in MultiPacking of 2-20-units (unlimited via grid connect)

• Ultra-low emissions • Minimal maintenance

C30 HP Net Power and Efficiency at Ambient Temperature, Sea Level

Compliances

UL 1741 UL 2200 IEEE 519

CEC Rule 21 NYPSC DG EPA Exempt

CA AQMD Exempt WY DEQ Exempt NEMA 3R / IP 14 Others*

• Direct2Grid

TM

interconnection

• No fluid storage, changes, disposal

• Uncontaminated exhaust heat for CHP

• Phase-to-phase balance (0-100%)

on stand-alone units

• Small footprint

• Vibration-free, quiet operation

• Easy indoor/outdoor/rooftop siting

• Zero hardware arraying (up to 600 kW) • Optional remote monitoring

Power Efficiency

30.0 27.5 25.0 22.5 20.0 17.5 15.0 12.5 10.0 7.5 5.0

2.5 0.0

30.0 27.5 25.0 22.5 20.0 17.5 15.0 12.5 10.0 7.5 5.0

2.5 0.0

-5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 8590 95100105110115120125 Ambient Temperature (F)

Other packaging options also available.

Performance

Natural gas/gaseous propane (52-55 psig)

Emissions:

NOx

Intake/Exhaust

Fuel flow (natural gas/gaseous propane-HHV) Exhaust gas temperature

Mass flow

Total exhaust energy

Power

30 kW net (+0/-1)

38.2 kVA max @ 480 VAC

<9 ppmV @ 15% O2 (<0.49 lb/MWh)

457,000 kJ/hr (433,000 Btu/hr) 275 ̊C (530 ̊F)

0.31 kg/s (0.68 lb/s)

327,000 kJ/hr (310,000 Btu/hr)

Heat Rate (LHV)

13,800 kJ (13,100 Btu) / kWh

Full Load Specifications @ ISO Conditions (15oC / 59oF @ sea level)

Dimensions

H: 1900mm (74.8”) W: 714mm (28.1”) D: 1344mm (52.9”)

Weight

478 kg (1052 lb) Add 173 kg (380 lb) for stand-alone option

Sound

65dBA @ 10 m (33 ft)

58dBA @ 10 m (33 ft) with optional silencer

CE LWA 98 compliant

* See www.microturbine.com/compliance for detail

Fuel heat content: 27.8 to 93.8 MJ/m3 (760 to 2616 Btu/scf) HHV; natural gas, propane, methane, ethane.

The manufacturer reserves the right to change or modify, without notice, the design or equipment specifications without incurring any obligation either with respect to equipment previously sold or in the process of construction. The manufacturer does not warranty the data on this document. Warrantied specifications are documented separately.

CAPSTONE TURBINE CORPORATION

www.microturbine.com

CAPSTONE C30 High Pressure Gaseous Fuels

Efficiency (LHV)

26% (± 2)

© 2002 Capstone Turbine Corp. • 05/2002 ss-HP • p/n: 512239-002

ISO Conditions

Net Power (kW)

Net Efficiency (%)

Image | Capstone C30 High Pressure Gascous Fuels



capstone-c30-high-pressure-gascous-fuels-
Capstone Turbine For Sale - Microturbine C30 C65 C200 C600 C800 C1000 - Go to microturbine website