Global Microturbine - Global Energy LLC


Publication Title | Capstone Integrated Fuel SystemTM For Use With Low-Pressure Natural Gas

Microturbine Search Engine Series

Capstone Turbine Publications search was updated real-time via Filemaker on:

Capstone Turbine Publications | Return to Search List

Search Completed | Title | Capstone Integrated Fuel SystemTM For Use With Low-Pressure Natural Gas
Original File Name Searched: cpst_copeland.pdf | Google It | Yahoo | Bing



Page Number: 001
Previous Page View | Next Page View

Text | Capstone Integrated Fuel SystemTM For Use With Low-Pressure Natural Gas | 001



Capstone Integrated Fuel SystemTM

For Use With Low-Pressure Natural Gas

Optional Accessory

The Product

Features

• Compression for one Capstone 60 or multiple Model 330s

• Single moving part

• Based on proprietary technology

• Hermetic design eliminates shaft seal leaks

• 8,000-hour maintenance interval • Outdoor enclosure

• Built-in variable speed

• Built-in safety devices

• 20,000 hr design life

• UL-Listed for Model 330s

Benefits

• Easy integration with one to three Model 330s or one Capstone 60

• Low inlet gas pressure capability • Once/year low-cost maintenance • Long life, proven reliability

• High efficiency

• Quiet operation

• Very low vibration

Fuel System Power Use vs. Pressure & Number of MicroTurbines

6

5

4

3

2

1

Operating Parameters:

• Min inlet pressure: 0.5 psig

• Max outlet pressure: 100 psig

• Max inlet temperature: 120o F

• Max outlet temperature: 150o F

Inlet Gas Requirements Clean, Dry Pipeline Quality

< 45 ppm H2S

< 150 ppm H2O < 2.5% CO2

4.4

3 Model 330s

3.3

2.6

2.6

2.5

1 - 2 Model 330s or one Capstone 60

2.4

(not rated for multiple Capstone 60s)

0.5 5 10 15 Inlet Pressure (psig)

Note: Requires Capstone M3XEHPFKIT external fuel kit.

Performance Specifications Under ISO Conditions (15o C / 59o F @ sea level)

• Ambient temp range: 14-120o F* • Oil carry-over: <5 ppm

• Vibration: 3 mil @ 60 Hz

• Power: 4.5 kW @ 60 Hz

Service @ 8,000 hrs

• Top up oil level

• Clean air intake/exhaust screens • Replace inlet filter

• Replace oil separator

CAPSTONE TURBINE CORPORATION

Dimensions

H: 1178 mm / 42” W: 601 mm / 24” L: 1072 mm / 46”

Weight

250 kg / 550 lb

Typical Sound Level

55 dBA @ 10 m

Note: Capstone reserves the right to change or modify without notice the design or equipment specifications without incurring any obligation either with respect to equipment previously sold or in the process of construction.

*Heat trace kit required for operation below 14 ̊F.

www.microturbine.com

© 2000 Copyright Capstone Turbine Corp. 11/2000 ss-IFS p/n: 511064-002