Text | Capstone Model C30, Low Pressure, Natural Gas, MicroTurbine systems using Foil Bearing Rotary Flow Compressor (FB RFC).N0002 | 001



Capstone

Service Notice SN0002

Date: From: Subject:

Affected

All Capstone Model C30, Low Pressure, Natural Gas, MicroTurbine systems using Foil Bearing Rotary Flow Compressor (FB RFC).

Summary

On the Model C30 Low Pressure MicroTurbine systems using FB RFC, when the FB RFC pump assembly is replaced, the new pump may not be properly controlled by the FB RFC Controller, due to a recent redesign and configuration change in the FB RFC pump assembly. Capstone requires that when the FB RFC pump assembly fails, both the pump assembly and the Controller be replaced with a new FB RFC Replacement Kit. The Kit Part Number is 516456 and is comprised of a FB RFC pump assembly and a Controller.

October 2003

Capstone Technical Support

Foil Bearing RFC Pump Replacement - Model C30 MicroTurbine

NOTE

If the FB RFC Controller fails, replace it with another Controller. Do not use the new FB RFC Replacement Kit (516456).

Capstone Technical Support

If you have additional questions, please contact:

Capstone Technical Support

Toll Free Telephone: (877) 282-8966 Service Telephone: (818) 407-3600 Facsimile: (818) 734-1080

E-mail: service@capstoneturbine.com

Capstone Technical Support (Japan)

Service Telephone: (818) 407-3700 Facsimile: (818) 734-1080

E-mail: servicejapan@capstoneturbine.com

450030-001 Rev A (October 2003)

Page 1 of 1

Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 • USA Telephone: (818) 734-5300 • Facsimile: (818) 734-5320 • Website: www.microturbine.com

This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.

Image | Capstone Model C30, Low Pressure, Natural Gas, MicroTurbine systems using Foil Bearing Rotary Flow Compressor (FB RFC).N0002



capstone-model-c30-low-pressure-natural-gas-microturbine-systems-using-foil-bearing-rotary-flow-compressor-fb-rfcn0002
Capstone Turbine For Sale - Microturbine C30 C65 C200 C600 C800 C1000 - Go to microturbine website

Search Engine Contact: greg@globalmicroturbine.com