Overview

SERIES 3000 FAULT CODES Sensor Faults

Series 3000 fault codes are assigned to sensor related faults. The following table shows the fault number, fault description, system severity level (SSL), isolation message, and comment for each fault. The trouble- shooting procedure for each message follows the table.

Fault No

Fault Description

SSL

Isolation Message

Comment

3000

TET1 OPEN

2

Internal Warning

3001

TET1 SHORT

2

Internal Warning

3002

TET2 OPEN

2

Internal Warning

3003

TET2 SHORT

2

Internal Warning

3004

BOTH TET FAILED

3

Internal Fault

3005

TET DELTA EXCEEDED

2

Internal Warning

3006

TCIN OPEN

2

Internal Warning

3007

TCIN SHORT

2

Internal Warning

3008

TCIN HIGH TEMP

2

Hi-Temp Warning

3009

TCIN LOW TEMP

2

Lo-Temp Warning

3010

FUEL TEMP OPEN

2

Internal Warning

3011

SPARE TC 1 SHORT

2

Internal Warning

Not Used

3012

SPARE TC 2 OPEN

2

Internal Warning

Not Used

3013

SPARE TC 2 SHORT

2

Internal Warning

Not Used

3014

BOARD TEMP HIGH

3

Hi-Temp Fault

3015

BOARD TEMP LOW

2

Lo-Temp Warning

3016

BOARD TEMP OPEN

3

Internal Fault

3017

BOARD TEMP SHORT

3

Internal Fault

3018

POWER SUPPLY HIGH

2

Internal Warning

3019

POWER SUPPLY LOW

2

Internal Warning

3020

SPEED DELTA EXCEEDED

3

Internal Fault

3021

PAMB FAILED

2

Internal Warning

3022

PAMB SHORT

2

Internal Warning

Not Used

3023

PAMB LOW

2

Hi-Alt Warning

3024

LOW FUEL PRESS

3

Internal Fault

3025

HIGH FUEL PRESS

2

Fuel Warning

Not Used

3026

LOW FUEL AIR PRESSURE

3

Internal Fault

Continued on next page

Observe Safety Precautions - Refer to Safety Instructions for Details

430001-001 Rev D (June 2003) 4-1 Model C30 Troubleshooting Guide

This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.