Text | Capstone Technical Support Cable Insulator for MOV Terminals | 001



Date: From: Subject:

January 2009

Capstone Technical Support Cable Insulator for MOV Terminals

Capstone

Capstone Turbine Corporation  21211 Nordhoff Street  Chatsworth  CA 91311  USA Telephone: (818) 734-5300  Fax: (818) 734-5320  Website: www.capstoneturbine.com

Service Bulletin SB0094

Systems Affected

Capstone Model C60/C65 MicroTurbine® systems shipped between June 1, 2007 and January 14, 2009, with the following Serial Numbers:

2301 2303-4 2308-9 4042-4048 4063 4102-4113 4117-4123 4199-4210 4212-4218 4228-4213 4214-4218 4228-4231 4253-4259 4262-4272 4274-4275 4285-4302

Summary

4310 4313-4325 4328-4330 4372-4377 4380 4384-4393 4397-4404 4412-4438 4472-4476 4485-4504 4507-4510 4516-4527 4564-4568 4570-4578 4581-4624 4646-4649

4652-4700 4704-4705 4707-4710 4712-4715 4719-4725 4727-4729 4731-4734 4736 4740-4750 4755 4758-4722 4776 4778-4793 4820-4825 4827-4830 4835-4858

4861-4897

4900-4931

4965

4970-4975

4976-4987

4989-5006

5009-5011

5014-5017

5023-5025

5032-5034

5036-5046

5048-5049

5064

5066-5075

5078 1000000002-1000000021

have MOV

contact with the post could receive an electrical shock. Covering the

terminal posts with a voltage of up to 480 VAC. An ASP who

Install cable insulators on MOV terminals. Capstone will provide the insulators free of charge for the affected systems. Contact Capstone Technical Support (see contact information at end of service bulletin) and request kit part number 610233-100. The kit includes Work Instructions, Cable Insulator for MOV Terminals Retrofit (440181).

450086 Rev A (January 2009) Page 1 of 2

Capstone reserves the right to change or modify without notice, the design, specifications, and/or contents of this document without incurring any obligation, either with respect to equipment previously sold or in the process of construction.

The affected systems

accidentally comes in

terminal posts will protect ASPs from an apparent shock hazard.

Required Action

Image | Capstone Technical Support Cable Insulator for MOV Terminals



capstone-technical-support-cable-insulator-mov-terminals
Capstone Turbine For Sale - Microturbine C30 C65 C200 C600 C800 C1000 - Go to microturbine website