Capstone

Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 • USA Telephone: (818) 734-5300 • Facsimile: (818) 734-5320 • Website: www.microturbine.com

Service Bulletin 0033

Date: From: Subject:

March 2002

Capstone Technical Support

Fuel Gas Booster Electrical Connections - Capstone 60 MicroTurbine

This Service Bulletin complements the Application Notes 512001 for installing the Copeland Fuel Gas Booster with the Capstone 60 MicroTurbine.

Affected

All Capstone 60 MicroTurbine systems that operate with the Copeland Fuel Gas Booster powered through the MicroTurbine electronics DC bus.

Summary

Capstone has noticed an incident of Pre-charge Board failures when operating with the Copeland Fuel Gas Booster. Failure can occur by enabling the Copeland Fuel Gas Booster prior to the MicroTurbine making direct connection between its DC bus and a power source such as the grid. In standby operation, the DC bus is only connected to the grid via resistors on the Pre-charge Board. Operating the Copeland Fuel Gas Booster in this state will cause excessive power draw through the Pre-charge Board leading to failure.

When installing the Fuel Gas Booster, the electrical connections between the Fuel Gas Booster and the MicroTurbine must be performed in the manner outlined below to avoid failure.

1. Ensure that there are no electrical connections between the MicroTurbine and the Fuel Gas Booster.

2. Power up the MicroTurbine.

3. Program the UCB relays per the instructions in the Application Notes 512001.

4. Power down the MicroTurbine.

5. Connect the Fuel Gas Booster control terminals to the correctly programmed UCB relays.

6. Connect the Fuel Gas Booster high voltage terminals to the MicroTurbine DC bus.

7. Power up the MicroTurbine and operate the system per the instructions in the

Application Notes 512001 and the MicroTurbine System Manual.

If you have additional questions, please contact: Capstone Technical Support

Telephone: (818) 407-3600 • Facsimile: (818) 734-1080

Toll Free Telephone: (877) 282-8966 • E-mail: service@capstoneturbine.com

513571-001 Rev A (Mar 2002) Page 1 of 1 SB0033

This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the equipment specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.

WARNING

Adhere to the Safety Precautions listed in the Application Notes 512001 and the MicroTurbine System Manual when servicing your MicroTurbine and associated equipment.

WARNING

Failure to comply with the above procedure will cause damage to MicroTurbine and void the warranty.