Text | Fuel Gas Booster Installation Instructions for Capstone 60 (Low Pressure Natural Gas Grid Connect Only) | 001



Capstone

Service Bulletin

Date: From: Subject:

January 2001

Capstone Customer Service

Fuel Gas Booster Installation Instructions for Capstone 60 (Low Pressure Natural Gas Grid Connect Only)

Capstone Customer Service Toll Free: (877) 282 - 8966 www.microturbine.com

Be sure to read and comply with the instructions contained within this Service Bulletin prior to installing the Capstone Fuel Gas Booster with the Capstone 60 (Low Pressure Natural Gas Grid Connect Only).

Also, refer to Service Bulletin SB0015 (512100 - 001) regarding installation of transient voltage suppressors.

Introduction:

The recommended inlet operating pressure for the Capstone 60 is between 75 and 77 psig. Applications in which the inlet supply pressure is less than 75 to 77 psig will require a Fuel Gas Booster. The Capstone Fuel Gas Booster is designed for operation with inlet pressures ranging from 2.0 to 7.0 psig. Higher supply pressures will require regulation down to within the 2.0 to 7.0 psig range.

The Fuel Gas Booster power consumption is adversely affected by increased inlet pressure, as the booster is a positive displacement compressor. Increased inlet pressure results in increased power consumption, which results in a decrease in overall system efficiency.

512001 - 001 (Jan 2001) Page 1 of 10 Service Bulletin SB0019

This information is confidential and proprietary to Capstone. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered.

Image | Fuel Gas Booster Installation Instructions for Capstone 60 (Low Pressure Natural Gas Grid Connect Only)



fuel-gas-booster-installation-instructions-capstone-60-low-pressure-natural-gas-grid-connect-only
Capstone Turbine For Sale - Microturbine C30 C65 C200 C600 C800 C1000 - Go to microturbine website

Search Engine Contact: greg@globalmicroturbine.com