Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 Service Bulletin SB0124 Incorrect Electronics Air Filter Installation

Required Action

At next



site visit:

Inspect the electronics air filter installation. If the support brace is not visible on the fresh air supply side, the filter assembly is installed correctly and no further action is required.

Electronics Air Filter Correctly Installed

(C1000 shown, C200 is similar)

If the support brace is visible on the fresh air supply side, the filter assembly must be removed and installed with the support brace to the inside regardless of air flow direction label.

See Work Instruction 440213 steps 2c (C200 systems) and 2e (C1000 Series systems) to remove filter.

Use low pressure air to thoroughly clean filter media.

Turn filter assembly around so support brace is to the inside.

See Work Instruction 440213 steps 3b (C200 systems) and 3d (C1000 Series systems) to reinstall filter assembly.





• • •

450138 Rev A (April 2014) Page 2 of 3

This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.

Copy is uncontrolled; user is responsible for verifying current revision.