Overview

SERIES 10000 FAULT CODES Inverter Faults

Series 10000 fault codes relate to the inverter. The following table shows the fault number, fault description, system severity level (SSL), isolation message, and comment for each fault. The trouble- shooting procedure for each message follows the table.

Fault No

Fault Description

SSL

Isolation Message

Comment

10000

IDSP CSUM

6

Internal Fault

10001

IDSP RAM FAIL

6

Internal Fault

10002

IDSP ADC CONV

4

Internal Fault

10003

IDSP ADC ACC

3

Internal Fault

10004

IDSP INTRDSPCOM

4

Internal Fault

10005

IDSP IPM MODULE

2

Grid warning

10006

IDSP NEUT IGBT

2

Grid warning

10007

IDSP DC OV

4

Grid Fault

10008

IDSP OV A

4

Grid Fault

10009

IDSP OV B

4

Grid Fault

10010

IDSP OV C

4

Grid Fault

10011

IDSP UV A

4

Grid Fault

10012

IDSP UV B

4

Grid Fault

10013

IDSP UV C

4

Grid Fault

10014

IDSP OC A

2

Grid warning

10015

IDSP OC B

2

Grid warning

10016

IDSP OC C

2

Grid warning

10017

IDSP OVER FREQ

4

Grid Fault

10018

IDSP UNDR FREQ

4

Grid Fault

10019

IDSP DLTA FREQ

4

Grid Fault

10020

IDSP HTSK OTEMP

4

High Temp Fault

10021

IDSP HTSK OP

4

Internal Fault

Not Used

10022

IDSP HTSK SH

4

Internal Fault

Not Used

10023

IDSP CNTCTR OP

4

Internal Fault

10024

IDSP CNTCTR CL

4

Internal Fault

10025

IDSP SYNC TO

4

Grid Fault

10026

IDSP MODE CHG

4

Internal Fault

10027

IDSP GRID UNBL

2

Grid Warning

HEV Only

Continued on next page.

Observe Safety Precautions - Refer to Safety Instructions for Details

430013-001 Rev C (July 2003) 11-1 Model C60 Troubleshooting Guide

This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.

Image | Overview SERIES 10000 FAULT CODES Inverter Faults



overview-series-10000-fault-codes-inverter-faults
Capstone Turbine For Sale - Microturbine C30 C65 C200 C600 C800 C1000 - Go to microturbine website

Search Engine Contact: greg@globalmicroturbine.com