<!DOCTYPE html> <html> <head><title>Microturbine Search Engine Series | Capstone Turbine Publications | Overview SERIES 9000 FAULT CODES Generator Faults | 001</title></head><body> <meta name= "description"content=" Information Publications | Publications Search Engine | On Demand PDF Document Searches "/> <meta name="keywords"content="capstone turbine, microturbine, Capstone C30,Capstone C65,Capstone C200,Capstone C600,Capstone C800,Capstone C1000"/><a href="http://www.globalmicroturbine.com"><img src="logo.jpg"alt="Global Microturbine - Global Energy LLC "></a></p> <BR> Publication Title | Overview SERIES 9000 FAULT CODES Generator Faults<BR><p><b>Microturbine Search Engine Series </b></p><p>Capstone Turbine Publications search was updated real-time via Filemaker on:</p> <script type="text/javascript">tmonth=new Array("January","February","March","April","May","June","July","August","September","October","November","December"); function GetClock(){ d = new Date(); nday = d.getDay(); nmonth = d.getMonth(); ndate = d.getDate(); nyear = d.getYear(); if(nyear<1000) nyear=nyear+1900; document.getElementById('clockbox').innerHTML=""+tmonth[nmonth]+" "+ndate+", "+nyear+""; setTimeout("GetClock()", 1000); } window.onload=GetClock; </script> <div id="clockbox"></div></p><a href='../index.htm'> Capstone Turbine Publications | Return to Search List </a><BR><BR><p>Search Completed | Title | Overview SERIES 9000 FAULT CODES Generator Faults<BR> Original File Name Searched: C60_10_9000 Faults.pdf | <a href="https://www.google.com/search?q=C60_10_9000 Faults.pdf">Google It</a></a> | <a href="https://www.yahoo.com/search?q=C60_10_9000 Faults.pdf">Yahoo</a></a> | <a href="https://www.bing.com/search?q=C60_10_9000 Faults.pdf">Bing</a></a> </p><p><br /></p><BR> Page Number: 001<BR><a href="overview-series-8000-fault-codes-solenoid-faults-006.htm">Previous Page View</a> | <a href="overview-series-9000-fault-codes-generator-faults-002.htm">Next Page View</a><BR><TABLE border='1' style=width='1200'><TR><TD valign='top'> <p>Text | Overview SERIES 9000 FAULT CODES Generator Faults | 001</p><BR><BR><span style="" >Overview<br/><br/>SERIES 9000 FAULT CODES Generator Faults<br/><br/>Series 9000 fault codes relate to the MicroTurbine generator. The following table shows the fault number, fault description, system severity level (SSL), isolation message, and comment for each fault. The trouble- shooting procedure for each message follows the table.<br/><br/>Fault No<br/><br/>Fault Description<br/><br/>SSL<br/><br/>Isolation Message<br/><br/>Comment<br/><br/>9000<br/><br/>GDSP CHECKSUM<br/><br/>7<br/><br/>Internal Fault<br/><br/>9001<br/><br/>GDSP RAM FAIL<br/><br/>7<br/><br/>Internal Fault<br/><br/>9002<br/><br/>GDSP ADC CONVERT<br/><br/>6<br/><br/>Internal Fault<br/><br/>9003<br/><br/>GDSP ADC ACCURACY<br/><br/>6<br/><br/>Internal Fault<br/><br/>9004<br/><br/>GDSP EXT COM<br/><br/>2<br/><br/>Internal Fault<br/><br/>Not Used<br/><br/>9005<br/><br/>GDSP IPM MODULE<br/><br/>6<br/><br/>Internal Fault<br/><br/>9006<br/><br/>GDSP BRAKE IGBT<br/><br/>6<br/><br/>Internal Fault<br/><br/>9007<br/><br/>GDSP DCBUS OVRVLT<br/><br/>6<br/><br/>Internal Fault<br/><br/>9008<br/><br/>GDSP OCURRENT A<br/><br/>6<br/><br/>Internal Fault<br/><br/>9009<br/><br/>GDSP OCURRENT B<br/><br/>6<br/><br/>Internal Fault<br/><br/>9010<br/><br/>GDSP HTSNK OTEMP<br/><br/>6<br/><br/>Hi Temp Fault<br/><br/>9011<br/><br/>GDSP HANDOFF FAIL<br/><br/>6<br/><br/>Internal Fault<br/><br/>9012<br/><br/>GDSP BRAKE OTEMP<br/><br/>2<br/><br/>Internal Fault<br/><br/>9013<br/><br/>GDSP HTSNK SHORT<br/><br/>6<br/><br/>Internal Fault<br/><br/>Not Used<br/><br/>9014<br/><br/>GDSP HISNK OPEN<br/><br/>6<br/><br/>Internal Fault<br/><br/>Not Used<br/><br/>9015<br/><br/>GDSP FAN FAIL<br/><br/>2<br/><br/>Internal Warning<br/><br/>9016<br/><br/>GDSP DIG OTEMP<br/><br/>6<br/><br/>Internal Fault<br/><br/>9017<br/><br/>GDSP DIG BUS OV<br/><br/>6<br/><br/>Internal Fault<br/><br/>9018<br/><br/>GDSP PWR RESET<br/><br/>2<br/><br/>Internal Fault<br/><br/>9019<br/><br/>GDSP ILL ADDR<br/><br/>2<br/><br/>Internal Fault<br/><br/>9020<br/><br/>GDSP SW RESET<br/><br/>2<br/><br/>Internal Fault<br/><br/>9021<br/><br/>GDSP WATCHDOG<br/><br/>2<br/><br/>Internal Fault<br/><br/>9022<br/><br/>GDSP DCBUS UV<br/><br/>6<br/><br/>Internal Fault<br/><br/>9023<br/><br/>GDSP PWR DIR<br/><br/>7<br/><br/>Internal Fault<br/><br/>Observe Safety Precautions - Refer to Safety Instructions for Details<br/><br/>430013-001 Rev C (July 2003) 10-1 Model C60 Troubleshooting Guide<br/><br/>This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.<br/><br/></span></TD><TD valign='top'><p>Image | Overview SERIES 9000 FAULT CODES Generator Faults</p><BR><BR><img src='../images/overview-series-9000-fault-codes-generator-faults-001.jpg' alt='overview-series-9000-fault-codes-generator-faults ' style='margin-left:20px;border-style:solid;border-width:1px;border-color:black;'> </TD></TR></TABLE><table border=1px solid blackstyle =width:50%> <tr> <td><b>Capstone Turbine For Sale </b>- Microturbine C30 C65 C200 C600 C800 C1000 - <a href="http://www.globalmicroturbine.com">Go to microturbine website</a> </td> </tr> </tr> </table> <p> </p> <script> (function(i,s,o,g,r,a,m){i['GoogleAnalyticsObject']=r;i[r]=i[r]||function(){ (i[r].q=i[r].q||[]).push(arguments)},i[r].l=1*new Date();a=s.createElement(o), m=s.getElementsByTagName(o)[0];a.async=1;a.src=g;m.parentNode.insertBefore(a,m) })(window,document,'script','https://www.google-analytics.com/analytics.js','ga'); ga('create', 'UA-85515761-1', 'auto'); ga('send', 'pageview'); </script><address> <p>Search Engine Contact: <a href="mailto:greg@globalmicroturbine.com?subject="Microturbine">greg@globalmicroturbine.com</a></p><p><br /></p></body></html>