Text | Service Notice SN0036 C200 Version 1.71 Software Release | 001



Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 • USA Telephone: (818) 734-5300 • Fax: (818) 734-5320 • Web: www.capstoneturbine.com

Service Notice SN0036

Date: From: Subject:

February 2014

Capstone Technical Support

C200 Version 1.71 Software Release

Systems Affected

Capstone Model C200 and C1000 Series (including C600/C800/C1000) MicroTurbine® systems operating released software v1.70. Sites running a beta or custom release contact Capstone Customer Service.

Summary

Version 1.71 software provides high inlet temperature detection and corrects a cause of erroneous flameout faults.

Version 1.71 Summary of Changes

• Adds high inlet temperature detection logic to allow TCIN temperature sensor to read temperatures above 212°F (100°C).

• Adds new fault “3043 – EXHAUST FLOW” to assist troubleshooting when TCIN is greater than 250°F (121°C).

• Changed TET error rate from a calculated value to a fixed value. This reduces the incidence of TET calculation errors that caused erroneous flameout faults with v1.70.

Recommended Action

• Install C200 software v1.71 at next site visit for all systems operating released software v1.70. Sites running a beta or custom release should contact Capstone Customer Service.

Responsibility

It is Capstone’s responsibility to:

• Provide this Service Notice containing a description of the software and a recommended action to Capstone's Authorized Service Providers.

• Make available the software, at no charge, to Authorized Service Provider for the resolution of issues or enhanced functionality related to fielded microturbine systems and accessories.

• For systems under warranty or FPP: o Laborwillnotbereimbursed.

o Travelwillnotbereimbursed.

450128 Rev A (February 2014) Page 1 of 2

This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.

Copy is uncontrolled; user is responsible for verifying current revision.

Image | Service Notice SN0036 C200 Version 1.71 Software Release



service-notice-sn0036-c200-version-171-software-release
Capstone Turbine For Sale - Microturbine C30 C65 C200 C600 C800 C1000 - Go to microturbine website

Search Engine Contact: greg@globalmicroturbine.com