Technical Reference Capstone Model C30 Performance

Introduction

This document presents performance information for the Capstone Turbine Corporation Capstone (recuperated) Model C30 MicroTurbine operating on natural gas (B Range) fuel.

The Capstone Model C30 MicroTurbine system is a compact, low emission, power generator providing up to 30 kW of electrical power. The Model C30 MicroTurbine generates electricity from various fuels with low exhaust emissions. Solid-state power electronics allow Grid Connect, Stand Alone, or HEV operation.

ISO Full Load Performance

Performance is listed at full load power and ISO conditions for the Capstone Model C30 MicroTurbine operating on natural gas (B Range) fuel, as defined in the Capstone MicroTurbine Fuel Requirements Technical Reference 410002. ISO conditions are defined as: 15 °C (59 °F), 60% relative humidity, and 101.325 kPa (14.696 psia) (standard sea level pressure). Other items are defined as: HHV: Higher Heating Value, LHV: Lower Heating Value, HPNG: High Pressure Natural Gas, and LPNG: Low Pressure Natural Gas.

Table 1 presents the (recuperated) Model C30 MicroTurbine performance for HPNG, LPNG, and Liquid Fuel applications.

Table 1. Model C30 MicroTurbine Performance (Grid Connect/Stand Alone)

Performance

HPNG Values

LPNG Values

Liquid Fuel Values

Rated Output

30.0 (+0/-1) kW

28.0 (+0/-1) kW

29.0 (+0/-1) kW

Thermal Efficiency

26.0 (+/-2)% LHV

25.0 (+/-2)% LHV

25.0 (+/-2)% LHV

Fuel Flow (LHV Based) (See Notes 1 and 2)

415,000 kJ/hr (394,000 Btu/hr)

404,000 kJ/hr (382,000 Btu/hr)

417,000 kJ/hr (395,000 Btu/hr)

Fuel Flow (HHV Based) (See Notes 1 and 2)

457,000 kJ/hr (433,000 Btu/hr)

444,000 kJ/hr (420,000 Btu/hr)

459,000 kJ/hr (435,000 Btu/hr)

Heat Rate (LHV Based) (See Notes 1 and 2)

13,800 kJ/kWhr (13,100 Btu/kWhr)

14,400 kJ/kWhr (13,700 Btu/kWhr)

14,400 kJ/kWhr (13,700 Btu/kWhr)

Exhaust Temperature

275 °C (530 °F)

275 °C (530 °F)

275 °C (530 °F)

Exhaust Heat Energy

327,000 kJ/hr (310,000 Btu/hr)

327,000 kJ/hr (310,000 Btu/hr)

327,000 kJ/hr (310,000 Btu/hr)

Exhaust Mass Flow

0.31 kg/s (0.68 lbm/s)

0.31 kg/s (0.68 lbm/s)

0.31 kg/s (0.68 lbm/s)

NOTE 1

These parameters are fuel-type dependent.

NOTE 2

The ratio of Higher Heating Value (HHV) to Lower Heating Value (LHV) is assumed to be 1.1.

410004-001 Rev B (June 2003) Page 1 of 14

This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.

Image | Technical Reference Capstone Model C30 Performance



technical-reference-capstone-model-c30-performance
Capstone Turbine For Sale - Microturbine C30 C65 C200 C600 C800 C1000 - Go to microturbine website

Search Engine Contact: greg@globalmicroturbine.com