Air Filter Replacement – Model C60

Introduction

This document describes instructions for replacing an air filter on the Capstone Turbine Corporation Model C60 MicroTurbine. The engine air inlet filter should be inspected periodically and replaced to ensure unrestricted flow of clean combustion and cooling air to the generator and turbine engine.

Refer to the MicroTurbine Standard Maintenance Schedule 440000 for recommended service intervals. Extreme conditions, especially in areas subject to wind and airborne dirt or dust, may require that the engine air inlet filter be inspected and changed more frequently.

Safety Precautions

Only Capstone Authorized Service Providers (ASP’s) should open the MicroTurbine and other equipment connected to the MicroTurbine. The systems can include multiple sources of power. Observe and adhere to the Safety Precautions listed below:

Checktoensurethattheinletfuelsupplyisshutoff.

AlwayschecktoensurethatyourMicroTurbineisde-energizedfrom

the utility. Isolate and lock out the utility (if applicable).

IsolateandlockoutanyothersourcesofpowertotheMicroTurbine. For example, connections to the solid state relays in the MicroTurbine communications bay.

OpentheStandAlonebatterycircuitbreaker,lockitintheOFFposition, and then unplug the battery cable.

Waitatleast5minutesafterdisconnectionfromutilitybeforeservicingto allow for electrical energy dissipation.

Verifythatnovoltageispresentonanyelectricalterminals.

Neverworkonenergizedequipment.

Observe all safety precautions to prevent Injury or death.

440051-001 Rev A (March 2003) Page 1 of 3

This information is proprietary to Capstone Turbine Corporation. Neither this document nor the information contained herein shall be copied, disclosed to others, or used for any purposes other than the specific purpose for which this document was delivered. Capstone reserves the right to change or modify without notice, the design, the product specifications, and/or the contents of this document without incurring any obligation either with respect to equipment previously sold or in the process of construction.

Image | Work Instructions Air Filter Replacement – Model C60



work-instructions-air-filter-replacement-–-model-c60
Capstone Turbine For Sale - Microturbine C30 C65 C200 C600 C800 C1000 - Go to microturbine website

Search Engine Contact: greg@globalmicroturbine.com